The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. This Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. All control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.


7444.00 

Learn More


FEATURES


  • Fully certified to BS EN54-2 and BS EN54-4
  • 2, 4 or 8 version zones
  • Available in Surface and Flush Mounting Options
  • Compatible for use on BS5839: Part 1: 2002 installations
  • 2-wire repeaters and ancillary boards
  • Fully programmable using simple menu options

    • Adjustable sounder delay time
    • Sounder configuration options
    • Zonal sounder delay detectors only
    • Zonal sounder delay call points only
    • Coincidence input selection
    • I.S Barrier selection by zone
    • Short circuit fire by zone
    • Non latching zones
    • Silent zones
    • Zone input delay
    • General panel configuration
  • Simple, single board construction
  • Installer friendly
  • Compatible with wide range of detection devices
  • Two monitored sounder outputs
  • 3 Amp power supply
  • Auxiliary power output


TECHNICAL SPECIFICATION


  • Construction : 1.2mm mild sheet steel
  • IP Rating : IP30
  • Finish : Epoxy powder coated
  • Colour - lid & box : BS 00 A 05 grey - fine texture
  • Colour - controls plate & labels : RAL 7047 light grey - satin
  • Weight : 6kg
  • Supply voltage : 230V AC (+10%/-15%)
  • Mains supply fuse : 1.6 Amp 250V
  • Power supply DC rating : 24V 3 Amps
  • Maximum battery size : 7Ah 12V (2 per panel)
  • Fault contact rating : 30V DC 1 Amp
  • Local fire contact rating : 30V DC 1 Amp
  • Fire contact rating : 30V DC 1 Amp
  • Sounder output rating : 0.5A per output (max 1.6A over all outputs)
  • Detection zone current : 1.6 milliamps
  • Detection zone EOL resistor : 6k8 5%
  • Active EOL : K14606K (optional)
  • Sounder output EOL resistor : 10k 5%
  • Cable capacity : 2.5mm² per terminal
  • Operating temperature : -5°C to +40°C
  • Operating humidity : <95% (non condensing)


FREQUENTLY ASKED QUESTIONS 


What End Of Line Resistors does the Sigma CP Require?

The Detection Zones on the Sigma CP Conventional require a 6K8 End of Line resistor. The Sounder Output requires a 10K5 End of Line Resistor.


Can A Fault From The Sigma CP Power Supply Be Monitored Remotely?

Yes, by taking a pair of cables from the ROV and the FLT and then connect these across the common and normally closed of the fault relay, anytime that fault relay goes closed this will put a short across the input and put a fault on the Kentec Sigma CP panels.


DATASHEET


Sigma-CP.pdf