C-TEC CFP702-2 two-wire CFP AlarmSense fire panel is designed to work with Apollo's AlarmSense range of detectors, call points, sounders and beacons. The C-Tech CFP702-2 2 zone fire alarm panel is LPCB certified to the latest revisions of EN54 parts 2 and 4, offers an array of user and installer-friendly features at a very competitive price. Supplied surface mountable with plastic enclosure and featuring four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/key switch entry. A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.


5374.00 

Learn More


FEATURES


  • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/ key switch entry.
  • Manufactured by C-TEC in the UK.
  • Eight AlarmSense zone circuits - compatible with Apollo's AlarmSense detectors, call points, sounders and visual indicators.
  • Four conventional sounder circuits.
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
  • Two on-board relays (Fire and Fault).
  • Two open-collector outputs (Remote and Reset).
  • 'Class change' and alert inputs.
  • Installer-friendly design.
  • Attractive flush or surface mountable plastic lid and enclosure - no bezel required.
  • Low 25mA quiescent current.
  • Multiple indicators.
  • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
  • Space for two x 12V 3.3Ah VRLA batteries.


TECHNICAL SPECIFICATION


Approvals/certificationsCertified to EN54-2/4 by the LPCB (0832-CPR-F0386).
Mains supply230V 50/60Hz.
Mains rated current350mA maximum.
Internal power supply19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to1.5A @ 230Vac (ImaxA eq 146mA).
Quiescent current25mA (mains failed, internal sounder active, PSU & gen fault LED lit).
Max battery size and type2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah.
No. of detector zone circuitsThe CFP708-2 has 8 AlarmSense zone circuits which are compatible with Apollo's AlarmSense range of detectors & call points AND sounders & visual indicators. (Max. length per circuit is 500m).
Call point resistor valueOnly use AlarmSense call points.
Max. devices per detector zone25 AlarmSense detectors/manual call points per AlarmSense zone. For AlarmSense sounder limitations per AlarmSense zone see 'Max. sounder output current' section.
No. of conventional sounder circuits4 - these are additional conventional (non-AlarmSense) sounder circuits; Max. length per circuit is 500m.
EOL resistor value6800Ω 5% Tol. 0/25W (blue, grey, red, gold).
Alarm voltage27V max, 20V min (final battery voltage)
Max. sounder output currentEach AlarmSense zone circuit & each conventional sounder circuit will support a max. sounder current of 200mA. Distribute sounder loads as evenly as possible. Total sounder loading per panel should not exceed 1.25A.
Auxiliary relaysTwo: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.
Open collector outputsTwo: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit voltage 27Vdc)
Other outputs24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed).
Auxiliary inputsTwo: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching)
Engineer (AL3) functionsProgram coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters alarm; Enter fault diagnostic facilities
Expansion connectionsYes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards.
Product dimensions (mm)380 W x 235 H x D 96mm.
Construction & finishPlastic lid and base; RAL7035 textured
IP RatingIP30
Weight1.75kg (without batteries).



DATASHEET


C-TEC_(Computionics_Limited)_-_CFP704-2_Datasheet_2020-07-13-141014.pdf